CWS 500N2
Highlights
- Most compact equipment
- Supporting BCI, Stripline and TEM cell applications
- Basic frequency range 9kHz up to 400MHz
- Extendable frequency range up to 1GHz
- Built-in 100W class A amplifier up to 400MHz
- Built-in RF switch to connect external amplifier
- Built-in directional coupler
- Built-in 3-channel power meter up to 1GHz
Top
Application
Top
Bulk current injection (BCI) testing
Bulk Current Injection (BCI) is a test procedure to proof the immunity to electrical disturbances by narrowband electromagnetic energy. The test signal is injected by means of a current injection probe physically being a current transformer laid around the wiring harness. Immunity tests are performed varying the level and the frequency of the injected test signal. The BCI test methode is widely known in the automotive industry as well as in the military/aircraft industry to test single components of a complex system.
The CWS 500N2 is designed to be used also for tests with TEM cell, Stripline and Parallel Plate as well as CDNs and EM clamps for tests according to EN/IEC 61000-4-6 and related standards.
The CWS 500N2 is designed to be used also for tests with TEM cell, Stripline and Parallel Plate as well as CDNs and EM clamps for tests according to EN/IEC 61000-4-6 and related standards.
Top
Standards
Top
- BMW GS 95002 (2001)
- DaimlerChrysler DC-10614
- EN 61000-6-1
- EN 61000-6-2
- Fiat 9.90110
- Ford ES-XW7T-1A278-AB
- Ford ES-XW7T-1A278-AC
- GMW 3097 (2001)
- GMW 3097 (2004)
- IEC 60601-1-2:2002
- IEC 61000-4-6
- IEC 61326
- IEC 61850-3
- ISO 11452-4
- ISO 11452-5
- Mercedes MBN 10284-2:2002
- MIL STD 461 D CS 114
- MIL STD 461 E CS 114
- PSA B21 7110
- Renault 36-00-808/--H
- RTCA/DO 160 Section 20
- SAE J1113-4
Top
Benefits
Top
BCI testing out of one single box - Easy, fast and reliable
The CWS 500N2 is the first compact solution world-wide for testing rf conducted immunity to narrowband radiated electromagnetic energy. Apart from the injection probe and the monitoring probe everything is in the box; controller, signal generator, amplifier, directional coupler and rf power measurement of up to three signals in parallel. A built-in rf switch allows to connect and use any external amplifier to extend the system's capabilities.
Despite of being that compact the CWS 500N2 is a very flexible solution and can be used in the laboratory as well as everywhere in the field. Setting up a test is done very quickly with a minimum effort for cabling of the test equipment. There are only two leads; the rf power lead to the input of the injection probe and the return lead from the monitoring clamp. The user doesn't need to be an expert to run reliable and reproducible tests.
A powerful software tool including extensive reporting features and instrument driving capabilites masters the test procedures. All operation is done by means of icd.control software.
Despite of being that compact the CWS 500N2 is a very flexible solution and can be used in the laboratory as well as everywhere in the field. Setting up a test is done very quickly with a minimum effort for cabling of the test equipment. There are only two leads; the rf power lead to the input of the injection probe and the return lead from the monitoring clamp. The user doesn't need to be an expert to run reliable and reproducible tests.
A powerful software tool including extensive reporting features and instrument driving capabilites masters the test procedures. All operation is done by means of icd.control software.
Top
Software
Top
icd.control - The software that makes your CWS 500N2 a complete rf test system
BCI tests are performed by means of the powerful and easy-to use icd.control remote control and documentation software. For this test application icd.control offers test procedures specifically written to the standards. Offering a library of standards tests are carried out as easy as ever possible.
But icd.control would not be an extraordinary tool without its outstanding and unique capability to implement up to four different measuring devices. These measuring instruments can be used for any kind of data acquisition controlling the entire test procedure. DUT monitoring is easier then ever before.
Even most complexe test routine can easily be programmed based on vector-defined test points.
icd.control is prepared to also cover test applications other than just BCI using e.g. Stripline, TEM Cells, CDNs and EM clamps.
But icd.control would not be an extraordinary tool without its outstanding and unique capability to implement up to four different measuring devices. These measuring instruments can be used for any kind of data acquisition controlling the entire test procedure. DUT monitoring is easier then ever before.
Even most complexe test routine can easily be programmed based on vector-defined test points.
icd.control is prepared to also cover test applications other than just BCI using e.g. Stripline, TEM Cells, CDNs and EM clamps.
Top
Other Models
Top
Continuous wave simulation from DC to 1GHz
Continuous wave simulation over 9 decades! The CWS 500N family not only covers the frequency range mostly required for industrial test applications based on IEC 61000-4-6 but EM TEST also offers dedicated solutions for the low frequency range as well as for BCI (Bulk Current Injection), TEM cell or Stripline applications in the automotive, aerospace and military area.
The CWS 500N4 covers the requirements as per IEC 61000-4-16 for low frequency test applications required for testing electrical and electronic equipment with the application of common mode disturbances to power supply, control, signal and communication ports.
The CWS 500N4 covers the requirements as per IEC 61000-4-16 for low frequency test applications required for testing electrical and electronic equipment with the application of common mode disturbances to power supply, control, signal and communication ports.
Top